Performance characteristics
— No mechanical movable parts, Impurities in water can’t be affected, and Long service life.
— Compared with the traditional mechanical water meter, the ultrasonic water meter can be measured and has a wide range of measurements. It can be measured when it has very small traffic.
— There are many alarm functions: Battery voltage can alarm, empty tubes or pipes that are not full of water, transducer fault alarm, and more
— Low-power design and the use of high-energy batteries, can work for 6 years or more.
— The communication interface is M-BUS and Rs485, it can easily achieve remote real-time monitoring and management on the LAN.
Flow parameter
DN | Flow range | Q4 | Q3 | Q2 | Q1 | Min reading | Max reading |
mm | Q3/Q1 | m³/h | m³/h | L/h | L/h | m³ | m³ |
15 | 400 | 3.125 | 2.5 | 10.0 | 6.3 | 0.00001 | 999 999 |
250 | 3.125 | 2.5 | 16.0 | 10.0 | 0.00001 | 999 999 | |
160 | 3.125 | 2.5 | 25.0 | 16.0 | 0.00001 | 999 999 | |
20 | 400 | 5 | 4 | 16.0 | 10.0 | 0.00001 | 999 999 |
250 | 5 | 4 | 25.0 | 16.0 | 0.00001 | 999 999 | |
160 | 5 | 4 | 40.0 | 25.0 | 0.00001 | 999 999 | |
25 | 400 | 7.875 | 6.3 | 25.2 | 15.8 | 0.00001 | 999 999 |
250 | 7.875 | 6.3 | 40.0 | 25.0 | 0.00001 | 999 999 | |
160 | 7.875 | 6.3 | 64.0 | 40.0 | 0.00001 | 999 999 | |
32 | 400 | 12.5 | 10 | 40.0 | 25.0 | 0.00001 | 999 999 |
250 | 12.5 | 10 | 64.0 | 40.0 | 0.00001 | 999 999 | |
160 | 12.5 | 10 | 102.4 | 64.0 | 0.00001 | 999 999 | |
40 | 400 | 31.25 | 25 | 100.0 | 62.5 | 0.00001 | 999 999 |
250 | 31.25 | 25 | 160.0 | 100.0 | 0.00001 | 999 999 | |
160 | 31.25 | 25 | 200.0 | 125.0 | 0.00001 | 999 999 | |
Size and Weight
DN | Length(L) | Width(B) | Height(H) | Thread | Thread | Weight |
(mm) | mm | mm | mm | d | D | Kg |
15 | 165 | 110 | 124 | R1/2 | G3/4B | 0.92 |
20 | 195 | 110 | 124 | R3/4 | G1B | 1.05 |
25 | 225 | 132 | 151 | R1 | G1 1/4B | 1.9 |
32 | 230 | 132 | 151 | R1 1/4 | G1 1/2B | 2.1 |
40 | 245 | 132 | 151 | R1 1/2 | G2B | 2.63 |
Performance parameter
Standby current | <7uA(dormancy) | Temperature class | T30 |
Data acquisition mode | Reluctance sensing | Pressure rating | MAP16 |
Operating voltage | 2.8~3.6V | Sensitivity level of flow field | U0/D0 |
Electromagnetic environment class | E2 | Environmental grade | O |
Storage environment | Ambient temperature:-25℃~55℃,Relative humidity:≤85% | ||
RS485 Smart Ultrasonic Water Meters
Range ratio: R200
Protection level: IP68
Maximum pressure: 1.6MPa
Maximum temperature: T50
Substrate: Copper
Connection method: Thread
Communication interface: M-BUS / RS485
Communication protocol: Modbus